Diagnose and repair a cold room that is not holding temperature

You are a Refrigeration Technician holding a refrigerant handling licence.

Simulated workplaceIntermediate missionCAQA Voltline Electrical

What is going on

Merriwa Cold Storage's cold room 3 alarmed overnight at minus 12 degrees against a set point of minus 20 and frozen product is at risk. Job J-26-1184 is open and van V-05 with recovery unit RU-02 and scale SCL-01 is on site. Leak detector LD-03 is away for its reference check so LD-01 from the workshop is in the van. The system is an R404A condensing unit on the roof with an evaporator in the room. The site manager reports the condenser fans sounded loud last week and that the unit has been short cycling. The refrigerant handling log shows a flare joint on cold room 2 was repaired two weeks ago, but cold room 3 has no recent history.

Carla Ferreira, Refrigeration and Air Conditioning Manager
Subject: Merriwa cold room 3 not pulling down, product at risk

Merriwa's cold room 3 alarmed overnight at minus 12 against a set point of minus 20 and there is product at risk. Marco is on his way with van V-05 and recovery unit RU-02. I want you to take the lead on the diagnosis: work through the control circuit and the refrigeration side logically, follow the refrigerant recovery procedure if the system has to be opened, and record everything on the job J-26-1184, the refrigerant handling log and the commissioning sheet. Leak detector LD-03 is at calibration, so use LD-01 from the workshop.

Your brief

Diagnose the fault logically across the electrical control circuit and the refrigeration circuit, isolate safely before any electrical work, recover and recharge refrigerant only if the system must be opened, leak test and commission the repair, and record everything on the job, the refrigerant handling log and the commissioning sheet so that the customer and the business have a complete record.

Work through it

You do not need to do it all. Doing a few of these will show you what the work is like. Your ticks and notes stay on this device.

What someone in this role would produce

  • Completed job safety analysis with isolation record
  • Fault diagnosis notes with readings and reasoning
  • Refrigerant handling log entry with recovered and charged masses and leak test result
  • Test results and commissioning sheet with final operating readings
  • Updated job record with repair details and customer briefing

Printing this is a record of what you explored. It is not a certificate or a qualification.